杏悦2官网

PRODUCT Position::HomePRODUCT—Transformer neutral grounding resistance cabinet
130a9e505cf8fedd2e6d6d7e519e56c5
Transformer neutral grounding resistance cabinet
Grounding the neutral point through a resistor can effectively limit intermittent arc grounding overvoltages,reduce system switching overvoltages,eliminate system resonance overvoltages,facilitate the configuration of single-phase grounding fault protection,and effectively remove faulty lines within a short period of time.This,in turn,lowers the insulation level of system equipment,extends the service life of system equipment,and enhances the safety and reliability of system operation.
15003226907 Consult Consult
Product Details
Transformer neutral grounding resistance cabinet

ENR-BNR series neutral grounding resistance cabinet

1.Overview

Grounding the neutral point through a resistor can effectively limit intermittent arc grounding overvoltages,reduce system switching overvoltages,eliminate system resonance overvoltages,facilitate the configuration of single-phase grounding fault protection,and effectively remove faulty lines within a short period of time.This,in turn,lowers the insulation level of system equipment,extends the service life of system equipment,and enhances the safety and reliability of system operation.

In the medium-voltage power distribution system,if the transformer is connected in a delta configuration,a Z-type grounding transformer needs to be installed to artificially introduce a neutral point for the system,so as to install a neutral grounding resistor.

The ENR-BNR transformer neutral grounding resistance cabinet integrates various electrical devices such as scattered Z-type grounding transformers(if the system does not have a neutral point lead-out,additional ones need to be installed),resistors,current transformers,measuring instruments,and grounding protection output terminals into a sealed metal cabinet.It can also be equipped with disconnectors and lightning arresters,supplied as a complete set,offering high safety and reliability.The layout is clear and tidy,facilitating installation,commissioning,operation,and maintenance.

Please inform us of the following parameters when placing an order

1.System rated voltage:(kV);

2.Short-time allowable current:(A);

3.Nominal resistance value:(Ω);

4.Whether to install a current transformer(CT):CT ratio and capacity,composite error;

5.Cable entry and exit mode:top-in bottom-out,bottom-in bottom-out,optional;

6.Short-term allowable flow time:(S);

7.Material of the resistance cabinet,cabinet(IP)protection level,color code,and installation location;

8.Is it necessary to install grounding recording and temperature and humidity control devices;

9.Is it necessary to install an isolating switch for maintenance purposes.